FEATURED DEPARTMENTS
XHHW-2
HOME  :  STORE  :  WIRE & CABLE  :  COPPER CONDUCTORS  :  XHHW-2
 | 1 of 6 |  View All(6 items)
031.gif
Zoom
Printer Friendly Email a Friend

XHHW-2

SKU: 708


pdf XHHW-2

  • 600 Volts
  • Copper Conductor
  • Cross-Linked Polyethylene Insulation (XLP)
  • High-Heat and Moisture Resistant
  • Sizes 14 Through 8 AWG Also Rated SIS
  • Black Sizes 2 AWG and Larger Sunlight-Resistant
  • Contact Us
    APPLICATIONS

    • Pro-Line Type XHHW-2 conductors are primarily used in conduit or other recognized raceways for services, feeders, and branch circuit wiring, as specified in the National Electrical Code.

    • XHHW-2 conductors may be used in wet or dry locations at temperatures not to exceed 90°C

    • Voltage rating for XHHW-2 conductors is 600 volts

    STANDARDS AND REFERENCES

    Pro-Line Type XHHW-2 conductors meet or exceed UL Standard 44, Federal Specification A-A-59544, and requirements of the National Electrical Code. Type XHHW-2 meets and exceeds all construction requirements of ICEA S-95-658 (NEMA WC 70) - Nonshielded 0 - 2 kV Cables, with testing frequencies based on UL requirements.

    CONSTRUCTION

    • Pro-Line Type XHHW-2 copper conductors are annealed (soft) copper. Insulation is an abrasion, moisture, and heat resistant cross-linked polyethylene (XLP)

    • Sizes 14, 12, and 10 AWG available in black, white, red, blue, yellow, green, orange, brown, purple, and gray

    • Conductor sizes 2 AWG and larger listed and marked sunlight resistant in black only

    ALTERNATE CONSTRUCTION
    • Pro-Line Type XHHW-2 copper conductors are also available in sizes 1/0 AWG and larger rated for cable tray use and sunlight resistant

    • Specify XHHW-2 for CT use when requesting quote or ordering

    WEIGHTS, MEASUREMENTS AND PACKAGING

    RECOMMENDED SPECIFICATIONS

    RECOMMENDED SAMPLE SPECIFICATIONS

    Conductors shall be UL-listed Type XHHW-2, suitable for operation at 600 volts or less in wet or dry locations, at temperatures not to exceed 90°C. Conductors shall be annealed copper. XHHW-2 shall be PRO-LINE WIRE & CABLE or approved equal.

    CABLE TRAY RELATED RECOMMENDED SAMPLE SPECIFICATIONS
    Conductor shall be UL-listed Type XHHW-2 rated for cable tray use and sunlight resistance. Also, suitable for operation at 600 volts or less in wet or dry locations, at temperatures not to exceed 90°C. Conductors shall be annealed copper. XHHW-2 shall be PRO-LINE WIRE & CABLE or approved equal.